Siemens cerberus pro fv- 922 cost
Also for use with HSeries detectors (see table 2) it does not require panel configuration as it will function the same as an ADBH11 which will not be synchronized.
#SIEMENS CERBERUS PRO FV 922 COST MANUAL#
For additional information please refer to the manual of related panel. Failure to configure the ABHW4B will cause problems. The ABHW4B must be configured by the panel when it is connected with FDUL detectors (see table 1). The NAC output must be set to a steady DC if it is used for ABHW4B. Ttapping of the notification appliance circuit is not allowed. The maximum device line resistance cannot exceed the maximum device line resistance specified in the compatible panels.
![siemens cerberus pro fv- 922 cost siemens cerberus pro fv- 922 cost](https://www.sipatec.org/files/uploads/MWV1.jpg)
number of loop powered ABHW4B audible bases. Refer to APPENDIXA in this document to calculate the max.
![siemens cerberus pro fv- 922 cost siemens cerberus pro fv- 922 cost](https://www.sipatec.org/files/uploads/OOH740.jpg)
load capacity and devices loaded in loop. The maximum number of loop powered ABHW4B is limited by the max. Refer to the related installation instructions of the auxiliary power supply. current rating and the power line resistance of the external power supplies applied on the ABHW4B. The maximum number of ABHW4B is related to the max. The alarm current of ABHW4B CAN T be energized by a 24V FWR power supply. If the alarm current of ABHW4B is energized by an external power supply, any UL listed 24VDC regulated power supply including the aux power output of XLS, FC200/FC901, FC202/FC200/FV202/FV200, FC922/FC924/FV922/ FV924 and PAD3/PAD4 can be used (refer to Figure 1) or a 24VDC NAC, such as PAD3/PAD4 (refer to Figure 3), ZIC4A (FireFinderXLS zone indicating card (NAC), refer to 2ģ Configuration Important! Figure 2) and NAC from FC200/FC901 (refer to Figure 4.1) or NAC from FC202/FC200/FV202/FV200, FC922/ FC924/FV922/FV924 (refer to Figure 4.2). ma External powered: High dba: 8.0 ma Low dba: 3. inch depth minimum 4 octagon box is NOT compatible Sound Output: High: 8dB Low: 7dB Tones: Steady Temporal 3 Temporal 4 Temporal 4 low power March time 120 Canadian March time 30 Electronic Ratings: Operating voltage: Loop power: 16 ~ 33 Vdc External power: 16 ~ 33 Vdc Supervisory current (max): From loop: 20 µa From external: 20 ua Alarm current (RMS max): Loop powered: High dba: 7. Building Technologies DivisionĢ Specifications Constraints Physical Specifications: Operating temperature: 32 F ~ 120 F (0 C ~ 49 C) Operating humidity: 10 ~ 9%RH (Non Condensing) Compatible electrical mounting boxes: 4 square gang box ONLY with 2. P/N A6V104087_c_en_ Siemens Industry, Inc.
![siemens cerberus pro fv- 922 cost siemens cerberus pro fv- 922 cost](https://cdn11.bigcommerce.com/s-gubc8u/images/stencil/1280x1280/products/68440/39462/S54400-C32-A2__24613.1581636059.jpg)
The ABHW4B can also meet requirement specified in UL464, UL207 and ULC2 except 20Hz requirements for Sleeping Area. When used in conjunction with listed, compatible Siemens equipment, the ABHW4B may be used in lieu of single/multiple station smoke alarms to achieve enhanced, systemlevel functionality. It meets or exceeds 8dB at 10 foot audibility requirement as specified in UL268.
![siemens cerberus pro fv- 922 cost siemens cerberus pro fv- 922 cost](https://www.sipatec.org/files/uploads/BA720.jpg)
The ABHW4B is a UL268 & ULCS29 listed smoke detector supplementary device which combines detector base and audible device functions. ABHW4B is fully compatible with all Siemens addressable detectors (see Compatible detectors section) and recognizes the detector type automatically. The ABHW4B provides Steady, Temporal 3, Temporal 4, Temporal 4 low power, March time 120 and Canadian March time 30. The ABHW4B audible bases in the same device loop are fully synchronized with FDUL detectors and also support RLHC, RLHW remote lamp. It is an intelligent supervised audible base which provides 6 selectable tone patterns, 2 volume levels and 2 different power types for alarm (loop power or external power) by using system configuration tool when ABHW4B used with the FDUL compatible detectors (refer to Compatible fire alarm control panels, Compatible detector, Detector Placement and Tone and Volume Selection ). consists of a standard base combined with an audible device. 1 Installation Instructions Model ABHW4B Intelligent Audible Base Introduction Application note The Model ABHW4B audible base from Siemens Industry, Inc.